Strategic value add

The economics behind PEG® — and beyond the racking

Real project numbers, one proof point, and how CatalystGrid extends the PEG® relationship into system-level DC optimisation and supplier-agnostic BESS integration.

01PEG® project economics

The numbers that open doors

Indicative cost impact of the PEG® platform versus conventional ground-mount and single-axis tracker structures, subject to project-specific validation.

2.1 MWper hectare land density
−40%lower steel & structure cost
−90%lower machine cost — no piling or concrete
−50%lower logistics cost — flat-pack shipping
−70%lower labour cost — unskilled local labour
−80%lower maintenance cost, low-profile design
−50%lower land acquisition cost per MW
50%/33%lower CAPEX vs single-axis trackers / fixed tilt
Subject to project-specific validation
02Proof point — Cullinan Solar PV

Cullinan-specific illustrative IRR / NPV case

Cullinan Ph1 (62.70 MWac / 82.15 MWp(dc)) + Ph2 (72.60 MWac / 95.08 MWp(dc)) — 135.30 MWac / 177.23 MWp(dc) combined. Traditional tracker vs. Jurchen PEG®, using ACES Renewables' updated Cullinan CAPEX & OPEX pricing (Sept 2026).

MetricWithout PEG®With PEG®Impact
Total CAPEXR1,787.4M / $96.6MR1,380.6M / $74.6M▼ 22.76%
Debt (70% gearing)R1,251.2MR966.4M▼ R284.8M
Equity (30% gearing)R536.2MR414.2M▼ R122.0M
Year-1 RevenueR286.4MR286.4MUnchanged
Year-1 OPEXR27.7MR22.2M▼ ≥20%
Equity IRR22.1%32.1%▲ +10.0pp
Equity NPV @ 14%R504.0MR841.8M▲ +67.0%

Where the R406.8M CAPEX saving comes from — Civil Works and Installation Works alone account for over three-quarters of it, led by PEG's foundation-free design and unskilled-labour install crews:

Civil Works — R164.6M (40.5%) Installation Works — R154.1M (37.9%) Mounting Structures — R61.3M (15.1%) Module Supply — R15.6M (3.8%) Spares (reclassified) — R11.2M (2.7%)

Illustrative model, not a lender financial-close run. Savings are led by faster, lower-labour installation and a simplified mounting structure — not a compromise on module count, warranty or design life (10-year warranty, extendable to 25-year, 25-year design life, SANS-verified structural & corrosion calculations). P50 energy 301.46 GWh/yr (Jurchen PVsyst, Cullinan combined at 130 MWac grid cap), degrading 0.55%/yr; PPA tariff R0.95/kWh escalating 5.5%/yr; 70/30 debt/equity gearing; 12% cost of debt, 15-yr amortizing tenor; 27% tax; 20-yr straight-line depreciation; 25-yr project life; 14% equity discount rate for NPV; R18.50/USD. CAPEX/OPEX per ACES Renewables' pricing model and Jurchen's written OPEX undertaking — tariff, debt and tax terms to be confirmed by ACES and lenders.

Download the Cullinan PEG vs Traditional comparison (PDF) ↗
03System topology

Direct DC-coupled BESS with DC optimisers

Routing strings through DC optimisers and coupling them directly to the BESS on the DC side — instead of separate AC-coupled inverter and battery-inverter stacks — changes the economics of a large, utility-scale grid-connected solar PV + BESS project:

−25%fewer combiners & disconnects
−25%fewer homerun cables
+40%higher-power inverters, lower cost per watt
40–70%of mismatch losses recovered
100%array utilisation vs ~84% without DC optimisation
+17%more energy yield over a 40-year project life

Fewer combiners, homeruns and transformers translate directly into lower installed cost per watt and a stronger LCOE case for every DC-coupled BESS project we touch.

04Storage integration

Supplier-agnostic BESS controllers — mix, match, and upgrade

Rather than locking a project into one battery manufacturer, CatalystGrid integrates a manufacturer- and trader-agnostic BESS power-plant controller and SCADA layer — so a project can mix and manage different BESS chemistries and vendors, including newer, lower-cost battery technologies, under one control system as they mature.

  • ✓Manufacturer- and trader-agnostic BESS integration & SCADA — not locked to a single battery vendor.
  • ✓Pre-qualified for ancillary services, with live monitoring, alarms and data.
  • ✓Agnostic interface to wind, solar PV and power-to-X co-located generation.
  • ✓Track record: Denmark's largest BESS portfolio — 350MW+ / 1GWh+ across 16+ projects, zero lost-time injuries.
  • ✓An agnostic control layer preserves optionality as next-generation, lower-cost long-duration storage technologies reach commercial maturity.

Want the full PEG® & BESS economics model for your site?

We'll run a site-specific PEG® layout, DC-coupled BESS topology comparison and LCOE analysis — typically within 48–72 hours.